Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Sci Rep ; 12(1): 19944, 2022 Nov 19.
Article in English | MEDLINE | ID: covidwho-2133605

ABSTRACT

Due to the shortage of personal protective equipment (PPE) during the COVID-19 pandemic, the interest and demand for sterilization devices to reuse PPE has increased. For reuse of face masks, they must be effectively decontaminated of potential infectious agents without compromising its filtration ability during sterilization. In this study, we utilized an atmospheric pressure pulsed dielectric barrier discharge (DBD), combined with nebulized liquid microdroplets to generate plasma-activated mist (PAM). MS2 and T4 bacteriophages were used to conduct the decontamination tests on two types of N95 respirators. Results showed at least a 2-log reduction of MS2 and T4 on N95 respirators treated in one cycle with 7.8% hydrogen peroxide PAM and at least a 3-log reduction treated in 10% hydrogen peroxide PAM. In addition, it was found that there was no significant degradation in filtration efficiency of N95 respirators (3M 1860 and 1804) treated in 10% hydrogen peroxide PAM found after 20 cycles. In terms of re-useability of masks after treatment as determined, it was shown that the elastic straps of 3M 1804 were fragmented after 20 treatment cycles rendering them unusable, while the straps of 3M 1860 were not negatively affected even after 20 disinfection cycles.


Subject(s)
COVID-19 , Respiratory Protective Devices , Viruses , Humans , N95 Respirators , Disinfection/methods , Water , Bacteriophage T4 , Hydrogen Peroxide , Pandemics
2.
Front Med ; 2022 Sep 24.
Article in English | MEDLINE | ID: covidwho-2041318

ABSTRACT

Nonpharmaceutical interventions (NPIs) have been commonly deployed to prevent and control the spread of the coronavirus disease 2019 (COVID-19), resulting in a worldwide decline in influenza prevalence. However, the influenza risk in China warrants cautious assessment. We conducted a cross-sectional, seroepidemiological study in Shandong Province, Northern China in mid-2021. Hemagglutination inhibition was performed to test antibodies against four influenza vaccine strains. A combination of descriptive and meta-analyses was adopted to compare the seroprevalence of influenza antibodies before and during the COVID-19 pandemic. The overall seroprevalence values against A/H1N1pdm09, A/H3N2, B/Victoria, and B/Yamagata were 17.8% (95% CI 16.2%-19.5%), 23.5% (95% CI 21.7%-25.4%), 7.6% (95% CI 6.6%-8.7%), and 15.0 (95% CI 13.5%-16.5%), respectively, in the study period. The overall vaccination rate was extremely low (2.6%). Our results revealed that antibody titers in vaccinated participants were significantly higher than those in unvaccinated individuals (P < 0.001). Notably, the meta-analysis showed that antibodies against A/H1N1pdm09 and A/H3N2 were significantly low in adults after the COVID-19 pandemic (P < 0.01). Increasing vaccination rates and maintaining NPIs are recommended to prevent an elevated influenza risk in China.

3.
Antimicrob Agents Chemother ; 65(8): e0035021, 2021 07 16.
Article in English | MEDLINE | ID: covidwho-1486470

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to spread rapidly worldwide. This study is the first to report the tolerability, safety, pharmacokinetics (PK), and immunogenicity of a recombinant human anti-SARS-CoV-2 monoclonal antibody, etesevimab (CB6, JS016, LY3832479, or LY-CoV016), in healthy adults. This paper describes a randomized, double-blind, placebo-controlled, phase 1 study. A total of 40 participants were enrolled to receive a single intravenous dose of either etesevimab or placebo in one of four sequential ascending intravenous dose cohorts. All 40 participants completed the study. Seventeen (42.5%) participants experienced 22 treatment emergent adverse events (TEAEs) that were drug-related, and the rates of these TEAEs among different dose cohorts were numerically comparable. No difference was observed between the combined etesevimab group and the placebo group. The exposure after etesevimab infusion increased in an approximately proportional manner as the dose increased from 2.5 to 50 mg/kg. The elimination half-life (t1/2) value did not differ among different dose cohorts and was estimated to be around 4 weeks. Etesevimab was well tolerated after administration of a single dose at a range of 2.5 mg/kg to 50 mg/kg in healthy Chinese adults. The PK profiles of etesevimab in healthy volunteers showed typical monoclonal antibody distribution and elimination characteristics. (This study has been registered at ClinicalTrials.gov under identifier NCT04441918.).


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Antibodies, Neutralizing , Antibodies, Viral , China , Double-Blind Method , Humans
SELECTION OF CITATIONS
SEARCH DETAIL